Dosimetric Comparison of Coplanar, Non-coplanar, and Mixed-Arc VMAT for Head and Face Skin Cancers: A Multi-scenario Analysis
1Department of Radiation Oncology, REM Radioterapia srl, Viagrande, Italy
2Department of Neurosurgery, Trauma Center, Gamma Knife Center, Cannizzaro Hospital, Catania, Italy
3Department of Medicine and Surgery, Kore University of Enna, Enna, Italy
4Department of Neurological Surgery, University of California, Davis, Sacramento, CA, U.S.A.
5Neurosurgical Unit, Department of Biomedicine, Neurosciences and Advanced Diagnostics (BiND), University of Palermo, Palermo, Italy
6Radiology Unit, Giovanni Paolo II Hospital, Ragusa, Italy
7Neurosurgery Unit, Department of Head and Neck Surgery, Garibaldi Hospital, Catania, Italy
Abstract
Introduction
Radiotherapy (RT) for head and face skin cancers (HFSC) poses significant challenges due to the proximity of highly radiosensitive organs at risk (OARs), such as the brain, lenses, and lacrimal glands (1-4). For instance, in the treatment of scalp tumors, the penetration depth of high-energy (MeV) photons complicates the effective sparing of underlying brain tissue. As a result, low-energy (kV) photons and electron beams are often considered preferable alternatives (5,6). While kV photons have become increasingly uncommon due to the progressive replacement of roentgen therapy equipment with modern linear accelerators (LINACs), LINAC-based electron beam radiotherapy (EBRT) remains a widely used and valid therapeutic option for HFSC (7).
EBRT is characterized by a steeper dose fall-off compared to MeV photons, reducing energy deposition beyond the target volume and thereby sparing adjacent healthy tissues. Typically, EBRT is delivered using an en face field, manually collimated with lead cutouts of various sizes and shapes to conform to the tumor geometry. The choice of electron energy and prescription isodose is guided primarily by tumor thickness (8). However, this approach is inherently imprecise, as it does not allow for rigorous control of the dose delivered to neighboring OARs (9). Furthermore, anatomical irregularities, such as those found in large scalp tumors or periorbital and nasal lesions, can cause significant dose perturbations within the target, leading to hot and cold spots that may increase toxicity or compromise local tumor control (10). These limitations arise because EBRT is most effective on flat surfaces, which are rarely encountered in the head and face region.
To mitigate these drawbacks, advanced electron dose calculation algorithms have been integrated into certain treatment planning systems (TPS), leading to the development of modulated electron radiotherapy (MERT) (11). However, these newer EBRT techniques remain largely unavailable, and their implementation is hindered by a lack of familiarity among radiation physicists (12). Consequently, photon-based RT, calculated
Compared to electrons, photon beams exhibit a more gradual dose fall-off in healthy tissues for the same prescription dose, thereby increasing the risk of radiation-induced toxicity. One strategy to minimize unnecessary OAR exposure is to optimize beam path distribution across multiple angles, either within the same plane or across different planes. This optimization is achievable through volumetric modulated arc therapy (VMAT) and non-isocentric robotic systems, such as CyberKnife (13,14).
VMAT can be delivered using either coplanar arcs (with the treatment couch fixed at 0˚) or non-coplanar arcs (with non-zero couch angles). The latter configuration has been shown to enhance OAR sparing in various tumor sites without compromising target coverage (15-17). However, the safe delivery of non-coplanar arcs requires precise setup verification, as even minimal positional errors introduced by couch rotation can impact dose distribution. Dedicated image-guidance systems, such as ExacTrac, facilitate accurate patient positioning and correction of setup deviations (18).
In this study, we evaluated the dosimetric differences in OAR and planning target volume (PTV) coverage among coplanar, non-coplanar, and mixed VMAT plans in five representative HFSC cases, using stereotactic dose delivery under ExacTrac guidance.
Patients and Methods
Following CT acquisition, images were imported into the Eclipse treatment planning system (TPS) (version 13.7, Varian Medical Systems, Palo Alto, CA, USA). The following volumes of interest were contoured: the clinical target volume (CTV), encompassing the macroscopic disease (gross tumor volume, GTV) and surrounding tissues at risk for subclinical tumor infiltration; the planning target volume (PTV), obtained by a 1 mm isotropic expansion of the CTV (excluding extensions beyond the body surface) to account for setup uncertainties; and the organs at risk (OARs), including the brain, eyes, and lenses. In cases of periorbital tumors, the lacrimal glands were also contoured.
Dose prescriptions were assigned based on tumor histology, with lower doses for basal cell carcinoma (BCC) and Merkel cell carcinoma (MCC) compared to cutaneous squamous cell carcinoma (CSCC).
Treatment plans were created for a TrueBeam Novalis STx linear accelerator equipped with a high-definition multileaf collimator and 6 MeV flattening filter-free photon beams. Non-coplanar arcs were planned with five couch rotations: 30˚, 60˚, 270˚, 300˚, and 330˚. These angles were simultaneously considered in all cases, except for the most extended PTVs (>100 cc) on the head surface, where the effect of reducing the number of non-coplanar arcs on the dose distribution was also evaluated.
The following dosimetric parameters were analyzed: 1) Target coverage and dose homogeneity: i) D98% (near-minimum dose), D2% (near-maximum dose), and D50% (median dose) were used to calculate the homogeneity index (HI) using the formula: HI=(D2%−D98%)/D50%, where values approaching 0 indicate better homogeneity. ii) The Paddick conformity index (CI) was used to assess the conformity of the 95% isodose to the PTV (20), with values approaching 1 indicating superior conformity. iii) The maximum dose (Dmax) was intended to be limited to 110% of the prescribed dose. 2) OAR dose constraints: i) The Dmax and mean dose (Dmean) were recorded for all OARs. ii) For the brain, the volumes receiving 70% (V70%) and 50% (V50%) of the prescribed dose were reported. iii) For cases where significant brain irradiation was expected (
All dose distributions were analyzed using dose-volume histograms. Intra-patient comparisons of the VMAT plans were conducted using identical optimization parameters for each case, as detailed in Supplementary Materials 1 and 2.
Additionally, co-VMAT, nonco-VMAT, and mxd-VMAT plans were compared in terms of total monitor units (MUs) and beam-on time (BOT).
Results
The prescribed dose was 30 Gy in five fractions, to be delivered twice weekly, with each plan normalized to ensure 98% target volume coverage. A 5-mm thick bolus was included in all plans to improve target coverage. Dose distribution and beam arrangements are shown in
Overall, the nonco-VMAT plan demonstrated superior dosimetric performance, achieving better conformity index (CI) and homogeneity index (HI), along with a lower hotspot compared to the other two techniques. Additionally, it resulted in improved OAR sparing. No differences in MU or BOT were observed among the three modalities.
For each target, three VMAT plans were generated. The collimator, gantry, and couch angle configurations used for plan generation are detailed in Supplementary Materials 4 and 5. All VMAT plans were normalized to ensure 98% of the PTV received at least 95% of the prescribed dose (
For the frontal target, none of the techniques achieved a maximum point dose below 110% of the prescription, though the mxd-VMAT plan was closest to this threshold (114%). The nonco-VMAT plan exhibited the highest Dmax (119.3%). Conversely, for the temporal-zygomatic target, both the nonco-VMAT (107.2%) and mxd-VMAT (108.7%) plans maintained acceptable Dmax values.
In terms of plan quality, the mxd-VMAT approach yielded a slightly superior HI for both tumor sites while maintaining CI comparable to the respective co-VMAT and nonco-VMAT plans. Regarding OAR sparing, the co-VMAT plan resulted in significantly higher doses to OARs for the right temporal-zygomatic target, whereas differences were negligible for the frontal target, except for the brain Dmax, which was lower in the mxd-VMAT plan. Plan sum evaluations confirmed no significant reciprocal dosimetric influence between targets. BOT was slightly longer with the nonco-VMAT technique for both sites.
Supplementary Materials 4 and 5 provide a detailed comparison of PTV indices, OAR dose parameters, MU, and BOT for the frontal and temporal-zygomatic targets, respectively. The OAR dose parameters derived from the plan sum analysis are reported at the end of Supplementary Material 5.
Regarding PTV parameters, the co-VMAT plan outperformed the nonco-VMAT and mxd-VMAT plans when using five non-coplanar arcs. The suboptimal results observed with five non-coplanar arcs (nonco-VMAT 5x), even when combined with two coplanar ones (mxd-VMAT 7x), prompted an evaluation of alternative arc configurations. By reducing the number of non-coplanar arcs, we identified that adding only the two least divergent non-coplanar arcs (30˚ and 330˚) to the coplanar ones provided a certain degree of OAR sparing, particularly for brain Dmean, as well as eye and lens dose parameters, without compromising PTV coverage. As a result, the mxd-VMAT 4x plan emerged as the most balanced solution. However, this plan had the second-longest BOT.
As in the previous case, solutions with fewer non-coplanar arcs were explored. The co-VMAT plan emerged as the best approach for both the initial and boost treatments. In the extended CTV plan, the only configuration that approached the performance of co-VMAT was the mxd-VMAT 4x plan, which reduced brain tissue exposure to medium doses (V50%, 260.38 cc
Supplementary Materials 8 and 9 summarize the dosimetric characteristics of the five plans, including PTV indices, OAR sparing, MU, and BOT for both the extended scalp target and the boost plan. The OAR dose parameters from the plan sums are provided at the end of Supplementary Material 9.
Discussion
To our knowledge, this is the first study specifically dedicated to assessing the usefulness of non-coplanar VMAT in treating cutaneous malignancies of the head and face. Existing reports on such arc arrangements primarily concern mucosal head and neck cancers, which, being located deeper, are more suitable for high-energy photon-based RT (16). Historically, kilovoltage roentgen therapy and electron beam RT have been preferred over megavoltage (MeV) photon-based RT due to their superior percentage depth dose curves, which spare underlying healthy tissues while achieving increased superficial dose deposition (21). However, as discussed earlier, both techniques have significant limitations (6). While MeV photon-based RT offers more precise dose distribution and greater adaptability for treating targets with curved shapes or variable thickness, it also results in higher OAR exposure to radiation (22). Increasing photon beam paths could improve both target coverage and OAR sparing. To test this hypothesis, we simulated VMAT plans with and without non-coplanar arcs in five distinct clinical scenarios.
Curative RT doses can be delivered through conventional fractionation (1.8-2 Gy/day) or ultra-hypofractionated schedules (≥5 Gy/fraction) (8). Skin cancers are more prevalent in elderly patients, whose comorbidities may limit compliance with long-course RT (23). Hypofractionation offers the advantage of reducing daily clinic visits while improving local control, as supported by recent evidence favoring dose escalation with stereotactic RT protocols (24). However, high-dose fractions also increase the risk of radiation-induced toxicity in peri-target OARs. This is particularly concerning when treating facial and scalp lesions, where OAR exposure must be carefully evaluated (25). The brain, in particular, is highly radiosensitive, especially in elderly patients, where radiation-induced cognitive impairment may be mistaken for age-related decline. Thus, its exposure should be minimized, as no radiation dose is entirely without risk (1). Conversely, the eyes, lenses, and lacrimal glands are generally well spared in stereotactic RT for HFSCs, even when located near the orbit (26). Given the high propensity for recurrence of these tumors and the potential need for re-irradiation, OAR dose constraints should adhere to the ALARA (As Low As Reasonably Achievable) principle to minimize cumulative toxicity (27). These considerations underscore the importance of advanced RT techniques that enhance target coverage while minimizing OAR exposure.
Our study demonstrated that non-coplanar VMAT arcs offer advantages in certain anatomical sites. In Case 1, the nonco-VMAT plan provided the best balance between dose homogeneity, conformity, and OAR sparing due to the tangential photon beam entrance to the temporal target, particularly when the couch angle was 270˚. This configuration maximized the tangential effect, further enhanced by a bolus compensating for the build-up region underdosing. Consequently, dose deposition beyond the inner layer of the skin target was reduced, improving conformity index (CI) and sparing underlying tissues compared to co-VMAT and mxd-VMAT plans. Rotational RT techniques inherently mitigate the skin-sparing build-up effect of high-energy photons by gradually making the radiation beam oblique to the skin surface (28). Accordingly, Cases 1 and 2, which had mirrored temporal-zygomatic targets (left in Case 1, right in Case 2), achieved optimal dosimetric results with non-coplanar arcs alone, even in the absence of bolus in Case 2. In contrast, for the frontal target in Case 2, the best-performing plan was the mxd-VMAT approach.
In Case 3, involving a bulky nasal root tumor partially obstructing vision, the nonco-VMAT plan significantly reduced dose exposure to all OARs, particularly the brain and lenses, while maintaining adequate target coverage and homogeneity.
In Case 4, the occipital target benefited most from the mxd-VMAT 4x plan, which achieved comparable PTV dosimetric parameters while slightly improving brain sparing compared to nonco-VMAT and co-VMAT plans.
Lastly, for the scalp target in Case 5, the co-VMAT plan outperformed all others for both the large CTV and smaller GTV boost. The concave shape of the scalp target encompassed a substantial portion of the brain, leading to a significantly higher mean brain dose than in the other cases. The mxd-VMAT approach further increased this dose due to oblique beam exits traversing the brain caudal to the scalp target's inferior border. However, adding two minimally angled non-coplanar arcs (30˚ and 330˚) to coplanar ones helped reduce medium-dose brain exposure (V50%) by increasing beam path dispersion. Notably, our TPS was unable to generate a satisfactory and deliverable nonco-VMAT plan for this case, making it the least favorable option.
By analyzing these five clinical scenarios, this study highlights the potential benefits of non-coplanar VMAT in HFSC treatment, identifying tumor sites where it is advantageous and where it may be counterproductive. However, safe implementation requires specific considerations. First, the critical anatomical location of HFSC necessitates meticulous setup verification to prevent both target miss and unintended OAR overexposure. We routinely employ the ExacTrac system, which reliably fulfils this task (29). Facilities lacking similar verification systems should be cautious in adopting non-coplanar arcs due to concerns about intrafraction motion during couch rotation. Second, the arc arrangements tested here do not necessarily represent the optimal configurations. Advanced path-finding algorithms could refine beam arrangements (30), but their discussion lies beyond this article's scope. Furthermore, the presence of surgical meshes, particularly titanium ones used for scalp cranioplasty, can cause dose perturbations such as backscattering to the skin flap (31). Finally, nonco-VMAT treatments generally require longer delivery times due to couch rotations and potentially increased MU requirements for adequate target coverage, which may affect patient compliance and comfort.
Given the variability in HFSC size, shape, and proximity to critical structures, no universal arc configuration can be recommended. Each case demands individualized beam arrangement optimization. This study offers insight into the potential dosimetric advantages of different VMAT strategies, encouraging practitioners to explore alternative solutions while carefully considering collision risks between the gantry and couch. The couch angles tested here were adapted from our standard intracranial stereotactic RT template (32), chosen for their uniform 30˚ spacing, which optimizes beam trajectory expansion without excessively prolonging treatment time.
Conclusion
This study is the first to demonstrate the potential advantages of incorporating non-coplanar arcs in the treatment of head and face skin cancers using commonly available LINACs and TPS platforms. While these five cases do not encompass all possible HFSC presentations, they offer practical guidance for treatment planning and challenge dosimetrists to refine VMAT strategies for improved therapeutic outcomes. Our findings underscore the need to individualize VMAT arc arrangements based on tumor location, as the addition of non-coplanar arcs may improve plan quality by enhancing target coverage and sparing organs at risk in selected cases. However, their implementation requires meticulous verification to avoid both missing the target and delivering excessive radiation doses to OARs. Moreover, the increased treatment duration associated with couch rotations and potentially higher monitor unit requirements may affect patient compliance and comfort compared to fully coplanar approaches. Further studies are warranted to validate these findings and refine arc selection strategies for clinical practice.
Supplementary Material
Available at: https://www.dropbox.com/scl/fi/746v86 kvqqdabhf1y2nua/Suppl.-materials-VMAT-def.pdf?rlkey= 086p4hqeiaiv9ff3g28ndkp1z&st=huq7mv04&dl=0
Conflicts of Interest
The Authors have no conflicts of interest to declare in relation to this study.
Authors’ Contributions
VZ collected patient data and contributed to drafting the first version; DLF performed dosimetric analysis; GEU, SL, PP, MN, AB, and GS provided critical analysis; GF conceptualized the project, contributed to drafting the first version, and revised the final manuscript. All Authors approved the final manuscript.
Funding
This manuscript did not receive any funds.